Lab Test Results

PORTABLE PERSONAL WATER FILTER TESTING RESULTS

The technology used in the Aqua Filter King™ water filtration systems have been developed through the research of aerospace scientists, medical researchers and water purification specialists with over 25 years of product development and success.

  • Bad Taste and Odors, Sediment and Suspended Items
  • Pathogens – Giardia, Cryptosporidium, cysts and spores
  • Industrial and Agricultural Toxic Wastes such as Trihalomethanes, TCE, PCB’s, DDT, DDD, Aldin, Dieldrin, Methoxychlor
  • Inorganics – Lead, aluminum, copper, mercury, and other heavy metalsRadiological – Radon 222

ORGANIC TESTING
(Volatile Organic Compounds-Organochlorine Pesticides)

ANALYTE PREFILTER CONCENTRATION UNITS % REDUCTION
Bromodichloromenthane* 250 µg\L >99.73
Bromoform* 250 µg\L >99.46
Acetone 250 µg\L >96.20
Benzene 250 µg\L >99.50
Chloroform 250 µg\L >99.50
Chlorobenze* 250 µg\L >99.20
Dibromochloromenthane* 250 µg\L >99.46
Carbon Tetrachloride 250 µg\L >99.63
1.1-1.2-1.4-Dichlorobenzenes 250 µg\L >99.71
1.1-1.2-Dichloroethane 250 µg\L >99.80
1.1-1.2-Dichloroethylence 250 µg\L >99.80
Ethylbenzene 250 µg\L >97.53
MTBE 250 µg\L >99.80
Styrene 250 µg\L >99.43
1.1.1-1.1.2-Trichlorothane 250 µg\L >99.76
Trichloroethylene 250 µg\L >99.76
Toluene 250 µg\L >98.00
Total Xylenes 250 µg\L >99.50
Alpha BHC 10 µg\L >97.50
Gamn BHC (Lindane) 10 µg\L >97.75
Heptachlor 10 µg\L >98.56
Endrin 10 µg\L >99.00
Ethylene Dibromido (EDB) 10 µg\L >95.00
Dibromochloropane (DBCP) 10 µg\L >98.00
Heptachlor-Epoxide 10 µg\L >98.7
4.4 DDD and DDT 10 µg\L >98.8
Methoxychlor 10 µg\L >94.6
PCB’s Arochlor-1260 20 µg\L >94.5
*Note: Compounds listed are Trihalomethanes

INORGANIC TESTING
(MBAS analysis-Trace Metals – Turbidity – Radiological)

ANALYTE PREFILTER CONCENTRATION UNITS % REDUCTION
Aluminum 2 m\l >90.0
Arsenic 100 mg\l >17
Cadmium 100 mg\l >85.75
Chromium 100 mg\l >93.72
Copper 100 mg\l >98.50
Lead 100 mg\l >98.00
Mercury 100 mg\l >99.25
Chlorine Residual 1.2 mg\l >94.1
Turbity 20 NTU >85.6
Total Suspended Solids 486 mg\l >99.0
Radon 222 540 pci\L >99.0

MICROBIOLOGICAL TESTING

ANALYTE PREFILTER CONCENTRATION UNITS % REDUCTION
Giardia 106 L >99.99
Cryptosporidium 106 L >99.9
E-coli 107 100ml >99.1
Testing Method: This testing information is based on an average of the four laboratories findings.  It should be understood that the results were obtained by using strict EPA, ANSI and NSF protocol and methodology. DESCRIPTION OF TESTING MEDTHODS: EPA METHOD 608, 524.2, 504, 505, 507 515.1, 531.1, 624 from EPA publication EPA 600/4-79-020, rev. 3/83, and ANSI/NSF Standard 53.